Overview
The Samlex America SEC-1250UL is a 12v 50-Amp 2-bank fully automatic battery charger. The charger features advanced switch-mode technology, providing high-efficiency charging in a lightweight and quiet design.
The SEC-1250UL is compatible with Flooded, AGM, and Gel Cell lead acid batteries. The charger can be configured as a 3-stage charger ideal for charging batteries while not in use. It also features a 2-stage charging profile, which is ideal when being used as a power supply or DC UPS with a battery.
The SEC-1250UL can be configured to a Half Power Mode option that reduces the maximum current to half its rating. This allows you to safely charge batteries at a lower capacity that might not be able to take the full 50 amps.
The Samlex SEC-1250UL features temperature/load-controlled fan cooling and has a heat sink built into the case to help dissipate the heat. It features several protections, including Short circuit, overload, reverse battery connection, and over-temperature.
Features
- Switch Mode Technology
- Safe for Flooded, AGM, & Gel
- Can charge 2 banks of batteries simultaneously, no isolator necessary
- Can be used as a power supply or DC UPS when used in conjunction with a battery
- Configurable 120 or 230 VAC
- Selectable 2 or 3-stage charging
- Half Power Mode Option
- Voltmeter and Ammeter for monitoring
- Fan controlled cooling
- 2-Year Warranty
Technical Specifications
- Dimensions (LxWxH): 13.03 x 9.6 x 3.82 in
- Weight: 9 lb
- Nominal Input Voltage (Factory Preset): 120 VAC, 50 / 60 Hz (108 to 132 VAC)
- Nominal Input Voltage (By Changing Internal Jumper): 230 VAC, 50 / 60 Hz (207 to 253 VAC)
- INPUT CURRENT At 120 VAC input / At 230 VAC input: 10.4 A / 5.6 A
- OUTPUT VOLTAGE: Voltages are applicable at battery temperature of 77˚ F / 25˚ C
- OUTPUT VOLTAGE - Bulk “I Phase”: 13.5 V ± 0.05V
- Absorption “Uo Phase”: 14 V / 14.4 V ± 0.05 V
- Float “U Phase”: 13.5 V ± 0.05 V
- MAXIMUM BULK CHARGING CURRENT, I - Normal Operation: 50A
- Half Power Mode: 25A ± 1A
- THRESHOLD OF CURRENT FOR CHANGE OVER From Float “U” To Absorption “Uo”: 10 A ± 1 A
- THRESHOLD OF CURRENT FOR CHANGE OVER From Absorption “Uo” To Float “U”: 5 A ± 0.5 A
- DURATION OF ABSORPTION STAGE “Uo”: 4 Hrs or 8 Hrs (Switch selectable)
- MAXIMUM BATTERY CAPACITY: 500 Ah
- TEMPERATURE COMPENSATION: Yes, with temperature sensor TF-500
- WIRED REMOTE PANEL (OPTIONAL): Yes, (model 900-RC)
- COOLING: Load Controlled Fan - ON at 10 A ± 1 A; OFF at 5 A ± 0.5 A
- PROTECTIONS: Overload, Short Circuit, Reverse Polarity, Over Temperature
- OUTPUT BANKS: 2
- OUTPUT CONNECTORS: Terminals with tubular holes (8 mm / 0.315” Dia) and set screw (M8)
- OPERATING TEMPERATURE RANGE: 0˚ - 40˚ C / 32˚ F - 104˚ F
- FUSES - AC INPUT SIDE (6.3 mm x 32 mm / .25” x 1.26”): Slow Blow / Time Delay - 12 A / 250 V
- FUSES - DC OUTPUT SIDE Automotive Blade Type e.g. Littelfuse “ATO” Series: 32 V, 60 A (2 pieces of 30 A in parallel)
- SAFETY COMPLIANCE: Intertek - ETL Listed. Conforms to ANSI / UL STD 1564
- EMI COMPLIANCE: FCC Part 15(B), Class B
- Shipping Weight: 12.0 lb
- UPC: 622988083037
- Manufacturer: Samlex
- Manufacturer’s Part Number: SEC-1250UL
- Model: SEC-1250UL